class EnsLib.Pipe.InboundAdapter
extends Ens.InboundAdapter, Ens.Util.Pipe
An Ensemble adapter wrapping up pipe functionality
parameter SERVICEINPUTCLASS = "%Stream.Object";
parameter SETTINGS = "CommandLine,Timer,Charset::selector?context={Ens.ContextSearch/CharacterSets},PipeMode";
List of properties can be set as settings in the configuration file
format is a comma separated list of property names
property Charset
as %String [ InitialExpression = "Native" ];
Character encoding scheme used to translate output to the file. For no encoding, use 'Binary'.
Other choices include:
Native - the default character encoding of the installed locale of the InterSystems IRIS server
latin1 - the ISO Latin1 8-bit encoding
ISO-8859-1 - the ISO Latin1 8-bit encoding
UTF-8 - the Unicode 8-bit encoding
Unicode - the Unicode 16-bit encoding (Little-Endian)
UnicodeBig - the Unicode 16-bit encoding (Big-Endian)
@<ttable> - <ttable> means a raw InterSystems character translation table name. A prefix of '@' means to use the named table.
property CommandLine
as %String(MAXLEN=2048);
property PipeMode
as %String [ InitialExpression = "WR" ];
property Timer
as %String;
method OnTask()
as %Status
default InboundAdapter behavior: always call ProcessInput on CallInterval