This page is used to set the ShutdownGroup of the production.
Note: Setting ShutdownGroup to a value other than default or empty value can lead to extending the time it takes to
stop the instance in a controlled manner. This can have implications for time sensitive failovers
Productions are requested to be shutdown in parallel when the system is stopped in a controlled manner
It is possible to control the shutdown order in separate parallel groups by entering an integer.
Running productions will be shutdown in parallel grouped by this integer.
The default if not specified will be taken as $$$ensDefaultShutdownGroup (2).
classmethod ApplyID(id, group)
as %String
[ ZenMethod ]
classmethod GetHyperEventResources(pMethod As %String = "")
as %String
Callback to return a list of resources required for a specific HyperEvent.
The user must have sufficient privileges on one of the resource/permission pairs
to be permitted to execute the hyperevent. An empty string implies the user already
has sufficient privileges for the ZenMethod specified in pMethod.
classmethod GetShutdownGroup(id)
as %Integer
[ ZenMethod ]
method OnGetRibbonInfo(Output pDisplay As %Boolean, Output pViewIcons As %List, Output pSortOptions As %List, Output pSearchBox As %Boolean, Output pRibbonTitle As %String, Output pCommands As %List)
as %Status
Get information to display in the ribbon bar.
method doApply()
[ Language = javascript ]
method doWarning()
[ Language = javascript ]
method getrecommendAndWarn()
[ Language = javascript ]
method onlayoutHandler(load)
[ Language = javascript ]
This client event, if present, is fired when the page
is first loaded or whenever it is resized.
If this is called at load time, then load will
be true.